JobStep Safety
  • Sourced from OSHA regulations and guidance
  • Updated November 2026
  • Every quote checked word for word
Which work does the plan cover?

A written plan under 1926.502(k) is only an option for these three kinds of work. For other work 6 feet or more above a lower level, use the fall protection 1926.501(b) lists for that kind of work.

Plan details
1. Why conventional fall protection is not used (k)(5)

Write the real reason at this site for each system. If one of them can be used, use it and leave this plan for the areas where none can.

2. Other measures (k)(6)
3. Controlled access zones (k)(7)
4. Safety monitoring system (k)(8)
5. Workers allowed in the zones (k)(9)
6. After a fall or near miss (k)(10)

Your plan

12 items are still blank. They print as lines to fill in by hand.

  • The kind of work (leading edge, precast concrete or residential) 1926.502(k)
  • The project name and site address 1926.502(k)(1)
  • The qualified person who prepared the plan 1926.502(k)(1)
  • The competent person who supervises the plan 1926.502(k)(4)
  • Where the copy is kept at the job site 1926.502(k)(3)
  • Why guardrail systems cannot be used or would create a greater hazard 1926.502(k)(5)
  • Why personal fall arrest systems cannot be used or would create a greater hazard 1926.502(k)(5)
  • Why safety net systems cannot be used or would create a greater hazard 1926.502(k)(5)
  • The other measures that reduce the fall hazard 1926.502(k)(6)
  • Each location where conventional fall protection cannot be used 1926.502(k)(7)
  • The safety monitor (a competent person) 1926.502(h)(1)
  • The workers allowed in the controlled access zones 1926.502(k)(9)

Everything runs in your browser; nothing you type is sent to us. The tool lays out your answers next to the rule each one meets. It does not decide whether a plan is justified at your site: that is the qualified person's call, and the standard is the authority.

When a written fall protection plan is allowed

Start with the default. In construction, the basic rule covers any open side or edge at least 6 feet above the next level down: the worker there needs a guardrail system, a safety net system or a personal fall arrest system. [OSHA] A written plan is the exception, and the standard says exactly who can use it:

“This option is available only to employees engaged in leading edge work, precast concrete erection work, or residential construction work (See § 1926.501(b)(2), (b)(12), and (b)(13)) who can demonstrate that it is infeasible or it creates a greater hazard to use conventional fall protection equipment.”

The burden sits with the employer. Each of those three paragraphs carries the same note: OSHA presumes at least one conventional system is feasible and safe, and the employer has to show otherwise before a plan replaces them. [OSHA] So if a harness and anchor, a net or a rail can work for part of the job, use it there and keep the plan for the spots where none can.

Kind of work at 6 feet or moreRuleCan a 1926.502(k) plan replace conventional systems?
Leading edge work1926.501(b)(2)(i)Yes, if the employer can show conventional systems are infeasible or create a greater hazard
Precast concrete erection1926.501(b)(12)Yes, if the employer can show conventional systems are infeasible or create a greater hazard
Residential construction1926.501(b)(13)Yes, if the employer can show conventional systems are infeasible or create a greater hazard
Unprotected sides and edges in other work1926.501(b)(1)No. Guardrail, safety net or personal fall arrest

For the crew briefing on the everyday rules, use the fall protection toolbox talk: edges, holes, harness checks and the rescue plan, ready to read aloud.

What a fall protection plan must include

Paragraph (k) lists ten provisions. This table puts each one in plain words and shows where the builder puts your answer. The full text of the first one:

“The fall protection plan shall be prepared by a qualified person and developed specifically for the site where the leading edge work, precast concrete work, or residential construction work is being performed and the plan must be maintained up to date.”

ParagraphWhat it requiresWhere it goes in the plan
1926.502(k)(1)Prepared by a qualified person, written for this one site, and kept up to date.Plan details: prepared by, site, date
1926.502(k)(2)Any change to the plan is approved by a qualified person.Change record at the end
1926.502(k)(3)A copy with all approved changes is kept at the job site.Plan details: where the copy is kept
1926.502(k)(4)A competent person supervises how the plan is carried out.Plan details: competent person
1926.502(k)(5)Says why guardrails, personal fall arrest and safety nets are infeasible here or would create a greater hazard.Section 1
1926.502(k)(6)Discusses the other measures that will reduce or remove the fall hazard, such as scaffolds, ladders or vehicle mounted work platforms.Section 2
1926.502(k)(7)Names each location where conventional fall protection cannot be used. Each one becomes a controlled access zone under 1926.502(g).Section 3
1926.502(k)(8)Where no other measure is in place, uses a safety monitoring system under 1926.502(h).Section 4
1926.502(k)(9)Names (or otherwise identifies) each worker allowed in the controlled access zones. Nobody else goes in.Section 5
1926.502(k)(10)After a fall or a related serious incident such as a near miss, the employer investigates, decides whether the plan must change, and makes the change.Section 6

Two of those rows point to other paragraphs. A controlled access zone follows 1926.502(g): it is marked by a control line or another means that restricts access, and a control line is set 6 to 25 feet back from the edge (6 to 60 feet, or half the member length, for precast erection). [OSHA] A safety monitoring system follows 1926.502(h): the monitor is a competent person on the same surface, in sight and in talking range of the workers, with no other duties that pull their attention away. [OSHA] The printout lists those rules under the matching section so the crew sees them too.

Fall protection plan template: what the printout holds

Press "Print the plan" and you get a fall protection plan template filled in with your answers: a details table (company, site, who prepared it, who supervises it, where the copy is kept), then six numbered sections that follow paragraph (k) from the reasons to the incident review. It closes with a change record and signature lines. Leave a field blank and it prints as a line, so the same button also gives you a blank template to fill in by hand. Choose "Save as PDF" in the print window for a file copy.

OSHA's own sample plans in Appendix E to Subpart M are a useful read before you write the reasons. OSHA labels them as non-mandatory guidelines and warns that their reasons are examples only:

“The reasons outlined in this sample fall protection plan are for illustrative purposes only and are not necessarily a valid, acceptable rationale”

In other words, copy the structure, not the excuses. Write what is true at your site: the roof pitch, the lack of an anchor point, the stage of framing, or whatever actually stops each system from working.

Qualified person and competent person

The plan needs both. A qualified person prepares it and approves every change. OSHA defines that person as:

“Qualified means one who, by possession of a recognized degree, certificate, or professional standing, or who by extensive knowledge, training, and experience, has successfully demonstrated his ability to solve or resolve problems relating to the subject matter, the work, or the project.”

A competent person supervises the plan on site. [OSHA] That person can recognize hazards that exist now or can be predicted, and is authorized to correct them promptly. [OSHA] Name both in the builder so their names print on the plan, and the crew knows who to ask.

How the fall protection plan builder works

  1. Pick the work. Tick leading edge, precast concrete or residential construction. If none fits, the tool tells you a plan is not an option.
  2. Fill in the details. Company, site, the qualified person, the competent person and where the copy will live.
  3. Give a reason for each system. One box each for guardrails, personal fall arrest and safety nets.
  4. Add the other measures, zones and people. Safer working surfaces, each location without conventional protection, how it is marked, the safety monitor and who may enter.
  5. Check the list and print. The tool lists every element still blank with its paragraph. Print, sign and keep the copy at the site.

Planning the task itself as well? A construction JHA breaks the work into steps with hazards and controls, and the risk assessment matrix scores each fall hazard before and after controls. If you build scaffolds as one of your other measures, run the scaffold inspection checklist before each shift.

Questions

Common questions

What is a fall protection plan?

In OSHA construction rules, it is a written, site-specific plan under 29 CFR 1926.502(k). It explains why guardrails, safety nets and personal fall arrest cannot be used for certain leading edge, precast concrete or residential work, and what will be done instead: other measures, controlled access zones, a safety monitor and named workers.

When is a fall protection plan required by OSHA?

Only when an employer doing leading edge work, precast concrete erection or residential construction can show that conventional fall protection is infeasible or creates a greater hazard. Then the plan is the required alternative. OSHA presumes at least one conventional system will work, and the employer has to prove otherwise.

Who can write a fall protection plan?

A qualified person: someone with a recognized degree, certificate or professional standing, or with extensive knowledge, training and experience, who has shown they can solve problems in that subject. A competent person then supervises how the plan is carried out on site.

Is there a free fall protection plan template?

Yes. The builder on this page is one: fill in what you know and print it, and anything you leave blank prints as a line to complete by hand. OSHA also publishes sample plans in Appendix E to Subpart M, which are non-mandatory examples for precast concrete and residential work.

Can a fall protection plan be used on a commercial roof or for general work at height?

Not under 1926.502(k). The option is written only for leading edge work, precast concrete erection and residential construction. Other work 6 feet or more above a lower level follows its own paragraph of 1926.501, which lists the systems allowed there.

Does the plan have to be kept on site?

Yes. A copy of the plan, with every approved change, is kept at the job site, and the plan is kept up to date. The printout from this tool has a line for where the copy is kept and a change record for the qualified person to sign.

More free safety tools

  • Risk assessment matrix: Click a 5x5 or 3x3 grid to score a hazard by severity and likelihood, before and after controls.
  • Scaffold inspection checklist: Answer the OSHA 1926.451 checks for a supported scaffold on your phone, see what is not met, copy a record or print the checklist with a sign-off line..
  • Emergency action plan template: Fill in your alarm, exit routes, assembly point, head count and contacts.
  • JHA template: A free job hazard analysis form in Word and PDF, laid out the way OSHA's sample form is, ready to print for the crew..
  • JSA template: A free job safety analysis form in Word and PDF: job steps, hazards and safe procedures, ready to print..
  • Incident report form, online: Fill in the free incident report form on your phone.
  • Toolbox talk topic picker: Tick what the crew is doing today and get the ready talks that fit, five sourced OSHA topics to build a talk around, and what the season adds..
  • Safety topic of the day: Today's two-minute safety talk, picked by date from a 31-day rotation, with the next six days listed so you can plan ahead..
  • All free safety tools for contractors

Sources